VZJ sign up for etocs
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suski, B.
Right arrow Articles by Revil, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Suski, B.
Right arrow Articles by Revil, A.
GeoRef
Right arrow GeoRef Citation
Agricola
Right arrow Articles by Suski, B.
Right arrow Articles by Revil, A.
Related Collections
Right arrow Hydraulic Conductivity
Right arrow Other Geophysical Methods
Right arrow Soil Physics
Published in Vadose Zone Journal 3:1193-1199 (2004)
© 2004 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA

SPECIAL SECTION: HYDROGEOPHYSICS

A Sandbox Experiment of Self-Potential Signals Associated with a Pumping Test

B. Suski, E. Rizzo and A. Revil*

CNRS-CEREGE, University of Aix-Marseille III, Dep. of Hydrogeophysics and Porous Media, BP 80, 13545 Aix-en-Provence, Cedex 4, France
* Corresponding author (revil{at}cerege.fr)

Received 23 February 2004.

The flow of water in a charged porous material is the source of an electrical field called the streaming potential. The origin of this coupling is associated with the drag of the excess of charge contained in the vicinity of the pore–water interface by the pore fluid flow. In this paper, we present a sandbox experiment to study this "hydroelectric" coupling in the case of a pumping test. A relatively thin Plexiglas tank was filled with homogeneous sand and then infiltrated with tapwater. A pumping test experiment was performed in the middle of the tank with a peristaltic pump. The resulting electrical potential distribution was measured passively at the top of the tank with a network of 27 nonpolarizable electrodes related to a digital multichannel multimeter plus an additional electrode used as a reference. A detectable electrical field was produced at the ground surface and analyzed with analytical solutions of the coupled hydroelectric problem. After the shutdown of the pump, the electrical potential and the piezometric level exhibit similar relaxation times in the vicinity of the pumping well. This means that the electrical potential measured at the ground surface can be used to track the flow of the groundwater and possibly to invert the distribution of the hydraulic transmissivity of the ground.




This article has been cited by other articles:


Home page
Vadose Zone JHome page
H. Vereecken, S. Hubbard, A. Binley, and T. Ferre
Hydrogeophysics: An Introduction from the Guest Editors
Vadose Zone J., November 1, 2004; 3(4): 1060 - 1062.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Soil Science Society of America Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2004 by the Soil Science Society of America.