VZJ sign up for etocs
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online 16 November 2005
Published in Vadose Zone J 4:1037-1047 (2005)
DOI: 10.2136/vzj2004.0138
© 2005 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Plauborg, F.
Right arrow Articles by Lærke, P. E.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Plauborg, F.
Right arrow Articles by Lærke, P. E.
GeoRef
Right arrow GeoRef Citation
Agricola
Right arrow Articles by Plauborg, F.
Right arrow Articles by Lærke, P. E.
Related Collections
Right arrow Water Content
Right arrow Field evaluation techniques
Right arrow Vadose Zone Processes and Chemical Transport

SPECIAL SECTION: SOIL WATER SENSING

In Situ Comparison of Three Dielectric Soil Moisture Sensors in Drip Irrigated Sandy Soils

Finn Plauborg*, Bo V. Iversen and Poul E. Lærke

Danish Institute of Agricultural Sciences, Department of Agroecology, Research Centre Foulum, P.O. Box 50, DK-8830 Tjele, Denmark
* Corresponding author (Finn.Plauborg{at}agrsci.dk)

Received 24 September 2004.

The number of different sensors available for measuring soil water content has increased since the introduction of time domain reflectometry (TDR). In this study the performances of the CS616 (Campbell Scientific, Ltd., Shepshed, UK) sensor and the Aquaflex (Streat Instruments., Ltd, Christchurch, NZ) sensor were compared with TDR using both vertically and horizontally installed sensors. It was found that the CS616 manufacturer's standard calibration needed to be linearly transformed, y = 0.59x + 0.01 (m3 m–3), to obtain accurate measurements in a sandy soil with horizontally installed probes. In two different soils the standard calibration performed better, and smaller corrections were found, y = 0.87x – 0.01 for a sandy loam and y = 0.96x – 0.001 (m3 m–3) for a sandy loam with a larger clay content, respectively. The CS616 sensor was most likely affected by electrical conductivity at 1.6 dS m–1 in the soil solution when measuring in drip-fertigated potatoes (Solanum tuberosum L.). In the period of fertigation, the sensor overestimated the soil water content in the sandy soil by 0.01 to 0.11 m3 m–3 compared with TDR measurements. The dynamic response of the vertically installed sensor to changes in soil water content was shown to be good, and the sensor may be useful for assessing threshold values in water content for the start and end of irrigation. The performance of the Aquaflex sensor was investigated in the sandy soil only, and the sensor was found to reflect the dynamics of soil water content well. However, the manufacturer's standard calibration underestimated the soil water content in the order of 0.10 m3 m–3 and even showed negative values.

Abbreviations: EC, electrical conductivity • TDR, time domain reflectometry • TDT, time domain transmission • VWC, volumetric water content







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Soil Science Society of America Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2005 by the Soil Science Society of America.