VZJ Download to Citation Manager
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online 26 May 2006
Published in Vadose Zone J 5:673-683 (2006)
DOI: 10.2136/vzj2005.0074
© 2006 Soil Science Society of America
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Figures Only
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McCartney, J. S.
Right arrow Articles by Zornberg, J. G.
Right arrow Search for Related Content
PubMed
Right arrow Articles by McCartney, J. S.
Right arrow Articles by Zornberg, J. G.
GeoRef
Right arrow GeoRef Citation
Agricola
Right arrow Articles by McCartney, J. S.
Right arrow Articles by Zornberg, J. G.
Related Collections
Right arrow Water Content
Right arrow Time Domain Reflectometry, TDR
Right arrow Soil Methods/Instrumentation

ORIGINAL RESEARCH

Correction of Lightning Effects on Water Content Reflectometer Soil Moisture Data

John S. McCartney* and Jorge G. Zornberg

Dep. of Civil Engineering, Geotechnical Group, Univ. of Texas at Austin, 1 University Station, C1792, Austin, TX 78712-0280
* Corresponding author (jmccartney{at}mail.utexas.edu)

Received 16 June 2006.

Soil moisture monitoring systems involving correlations with soil dielectric content measured using WCR (water content reflectometer) probes are susceptible to lightning-induced errors during field monitoring programs. These errors must be understood and corrected to use moisture data in geoenvironmental or hydrological applications. This study evaluated the effect of lightning on WCR measurements observed during the monitoring of four evapotranspirative landfill test covers. Several lightning strikes at the site caused unrealistic shifts in the inferred moisture content (from 0.001 to 3.900 m3 m–3), which showed a time-dependent decay. A conceptual model for lightning strike effects was developed that allowed correction of affected WCR data. Because duplicate probes were available in this project, WCR corrections could be calibrated by minimizing the difference between the data from affected probes with data from unaffected probes to within ±5 m3 m–3. This led to a correlation useful in other cases where duplicate probes were not available. Assessment of the consistency of the corrected data included evaluation of wetting fronts, comparison of moisture changes against meteorological patterns, and comparison of the corrected moisture content with upper- and lower-bound moisture content values.

Abbreviations: RC, resistor–capacitor • WCR, water content reflectometer







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Agronomy Journal Crop Science
Journal of Natural Resources
and Life Sciences Education
Soil Science Society of America Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 2006 by the Soil Science Society of America.