Fig. 6. Normalized relationship between the supply water pressure and the initial infiltration rate, with the infiltration rate being normalized by the saturated hydraulic conductivity of the medium, and the supply water pressure scaled by the absolute value of the breakthrough pressure as shown in Table 2. Fitted lines are also shown for both materials.
|