Fig. 6. Velocity of wetting front as detected by electrical resistivity probes located in boreholes surrounding Niche 3. Note that the fault intercepts BH9 and BH10 at a distance of 1.9 and 2.1 m, respectively, from their collars. The fault does not intercept BH1 and is approximately perpendicular to the borehole.