FIG. 9. Breakthrough curves calculated using the Two-Site Kinetic Model for a 10-cm-long soil column and the following parameters: q = 5 cm d–1,
= 0.5,
= 1 cm, Kd = 1 cm3 g–1, and
b = 1.5 g cm–3; on the left, fe = 0.4 and
k = 0.1, 0.5, and 10 d–1; and on the right,
k = 0.5 d–1 and fe = 0.1, 0.4, and 0.8.
|